45
V400-F050/250/350
User’s Manual
Sect
ion 3
Se
tt
in
g
RS-
232
C Communica
tion Cond
it
io
ns
Section 3
Setting RS-232C and Discrete I/O Communication Conditions
The default settings are indicated with an asterisk (*).
Setting item
Settings
Details
Baud Rate
9600*/19200/38400/
57600/115200
Select the desired baud rate (bps).
Parity
Select the desired parity. Parity is used to detect data failure.
None*
No parity will be used.
Odd
Odd parity will be used.
Even
Even parity will be used.
Data Length
8*/7
Select the data length to be used.
The data length is the number of bits required to send one
character.
Stop Bit
1*/2
Select the stop bit length to be used.
The stop bit indicates the end of data.
Baud rates exceeding 20 kbps are not defined in the RS-
232C standards. Therefore, if [38400 bps] or higher
baud rate is selected, communications may be
unreliable depending on the cable length.
If there are problems with communications, a baud rate
of [19200 bps] or below must be used.
Make the communication settings as follows when using save or load command (e.g. CB, CU).
Parity:
None,
Data Length:
8,
Stop Bit:
1
p.71