Changing Reading Conditions
The default settings are indicated with an asterisk (*). However, in the case of [Bank #00], [Exposure] will be
set for [Retry] as the default.
Color
Set the code cell color.
Black
The code will be read as a black code.
White
The code will be read as a white code.
Auto*
The color will be identified automatically.
Timeout
Enter the time (in msec) allowed before reading is completed after it is started.
100 to 9999
(2000*)
-
Retry
Set this item when you need to retry (capture the image twice or more) after reading is
executed. Capturing the image can be performed with a different exposure time.
None*
Capture will not be retried (i.e. capture will be performed only
once).
Exposure
Allows retry with different exposure time. Capturing the image can
be performed twice or more with a different exposure time.
For instance, if [02.00 msec] is set for [Step], [2 times] for
[Increment] and [2 times] for [Decrement], the exposure time will
be changed each time capture is performed, starting from 10 msec
to 12 msec, 8 msec, 14 msec and then 6 msec (if the original
exposure time is 10 msec).
Normal
Simple retry. Capture will be retried with the same reading
condition.
Step
0.01 to 05.00*
(0.30*)
Set the step (msec) in which the exposure time is changed.
This item can be selected only when [Exposure] is selected for
[Retry].
Increment
0 to 4 (2*)
Set the number of times (Times) the exposure time is to be
increased.
This item can be selected only when [Exposure] is selected for
[Retry].
Decrement
0 to 4 (2*)
Set the number of times (Times) the exposure time is to be
decreased.
This item can be selected only when [Exposure] is selected for
[Retry].
Interval
32 to 999 (100*)
Set the interval (msec) at which capture is to be performed.
This item can be selected only when [Normal] is selected for
[Retry].
Max Count
0 to 8 (4*)
Set the number of times (Times) capture is to be repeated.
This item can be selected only when [Normal] is selected for
[Retry].
Setting item
Settings
Details
It is possible to retry capturing the image twice or more with different reading
conditions.
“
Setting the Bank Switching Retry Function
” p.41
Summary of Contents for 2D CODE READER
Page 1: ...USER S MANUAL 2D Code Reader V400 F050 250 350 Cat No Z242 E1 03...
Page 13: ...12 Introduction Contents V400 F050 250 350 User s Manual Introduction MEMO...
Page 85: ...84 Section 6 Troubleshooting V400 F050 250 350 User s Manual Section 6 Troubleshooting MEMO...