106
Appe
ndix
Da
ta
Cap
acit
y
Tab
le
V400-F050/250/350
User’s Manual
Appendix
Data Capacity Table
The maximum quantity of information that can be stored depends on the symbol size of the
code. Also the maximum data capacity in relation to the amount of information carried by the
code depends on the character type and the arrangement and combination of characters. The
relation between the symbol size (number of cells) and data capacity is shown in the following
table.
DataMatrix
DataMatrix ECC200
In the following diagram, the symbol size is 12 × 12.
Symbol size
Data capacity
Numeral
Alphanumeric
Alphanumeric
and symbol
2-byte
character
1-byte
Japanese
character
10 × 10
6
3
3
-
1
12 × 12
10
6
5
1
3
14 × 14
16
10
9
3
6
16 × 16
24
16
14
5
10
18 × 18
36
25
22
8
16
20 × 20
44
31
28
10
20
22 × 22
60
43
38
14
28
24 × 24
72
52
46
17
34
26 × 26
88
64
57
21
42
32 × 32
124
91
81
30
60
36 × 36
172
127
113
42
84
40 × 40
228
169
150
56
112
44 × 44
288
214
190
72
142
48 × 48
348
259
230
86
172
52 × 52
408
304
270
101
202
64 × 64
560
418
372
139
278
8 × 18
10
6
5
1
3
8 × 32
20
13
12
4
8
12 × 26
32
22
20
7
14
12 × 36
44
31
28
10
20
16 × 36
64
46
41
15
30
16 × 48
98
72
64
23
47
12 cells
12 cells