Introduction
Always observe the following precautions to prevent operation failures, malfunctions, and
adverse effects on performance and equipment.
■
Installation of the Product
Do not install the product in the following locations:
•
Locations subject to ambient temperature that exceeds the rated temperature range
•
Locations subject to rapid changes in temperature (causing condensation)
•
Locations subject to relative humidity that exceeds the rated humidity range
•
Locations subject to corrosive or flammable gases
•
Locations subject to dust, salt, or metallic powder
•
Locations subject to direct vibration or shock outside the specified ranges
•
Locations subject to direct sunlight
•
Locations subject to oil or chemical spray
Ambient Temperature
•
Maintain a minimum clearance of 50 mm above and below the product to improve air
circulation.
•
Do not install the product immediately above significant heat sources, such as
heaters, transformers, or large-capacity resistors.
•
Do not let the ambient operating temperature exceed 45°C.
•
Provide a forced-air fan cooling or air conditioning if the ambient temperature is near
45°C so that the ambient temperature never exceeds 45°C.
Noise Resistance
•
Do not install the product in areas where high-
voltage equipment is installed.
•
Do not install the product within 200 mm of power
cables.
Precautions for Correct Use
POWER
OK
NG
Power cable
200mm min.
200mm min.
Main unit