47
V400-F050/250/350
User’s Manual
Sect
ion 3
Se
tt
in
g
RS-
232
C Communica
tion Cond
it
io
ns
Section 3
Setting RS-232C and Discrete I/O Communication Conditions
The default settings are indicated with an asterisk (*).
Setting item
Settings
Details
Input
Set the basic input format items.
Output
Set the basic output format items.
Prefix
None*/STX/ESC
Select the symbol that indicates the beginning (header) of the
command format.
No symbol will be selected if [None] is selected.
Suffix
CR*/CR+LF/ETX/LF
Select the symbol that indicates the end (footer) of the
command format.
FCS
OFF*/ON
Select whether to use the frame check sequence to detect data
input/output errors. Use of FCS will improve communication
reliability.
“FCS Check Program Example (BASIC)” p.104
Checker Data
OFF*/ON
Select whether to add a value that indicates the code quality
when the data is output.
Digit Data
Select whether to add a value that indicates the number of read data digits when the
data is output.
OFF*
No value will be added.
ON 2Byte
A 2-byte value will be added.
ON 4Byte
A 4-byte value will be added.
NG Output
OFF/ON*
Select whether to output an error code when reading fails.
Limit Data
OFF*/ON
Set the read data output range. If [ON] is selected, the settings
made for [Start Point] and [End Point] will be effective.
Start Point
001 to 999 (001*)
Enter the start digit position.
End Point
001 to 999 (999*)
Enter the end digit position.