Serial Interface Manual
OEL8000III Series Models K/X
Command: 902 Inquire System Version
Command Format:
Computer:
<SOH>i90200
Typical Response Message, Computer Format:
<SOH>i90200YYMMDDHHmmSOFTWARE# nnnnnn-vvv-rrrCREATED - YY.MM.DD.HH.mm&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. nnnnnn – Unit Type (ASCII text string)
3. vvv-rrr - Software revision level (ASCII text string)
4. YY.MM.DD.HH.mm - Date and time of software creation
5. && - Data Termination
6. CCCC - Message Checksum