5-8
Example
Print the range list and alarm list but do not print the
parameter list related to printing or the other parameter
list.
SFON, ON, OFF, OFF
SB
Sets whether interpolation is performed
or not.
Mode
Operation mode
Setting
SBp1, p2<terminator>
p1
Channel number (001 to 030)
Computation channel number (A01 to A30)
p2ON/OFF
Example
Perform step interpolation for channel 6 in slot 3.
SB036, ON
Comments
• If step interpolation is performed, the space between
recorded points is recorded .
• If two or more channels are step-interpolated in the
same position, the recording priority depends on the
recording color, and recording is done in the
following order:
Black > blue-purple > magenta > navy blue > red >
blue > brown > green > orange > yellow-green
For example, if two channels being recorded in black
and in blue are step-interpolated in the same position,
the overlapped parts are recorded in black.
• The optional computation channel number for a
stand-alone model is A01 to A30.
PT
Turns on or off every channel of trend
record.
Mode
Operation mode
Setting
PTp1, p2<terminator>
p1
Channel number (001 to 030)
Computation channel number (A01 to A30)
p2ON/OFF
Example
Turn on the analog recording of channel 6 in slot 3.
PT036, ON
Comments
• The optional computation channel number for a
stand-alone model is A01 to A30.
PD
Turns on or off every channel of digital
records.
Mode
Operation mode
Setting
PDp1, p2, p3<terminator>
p1
Channel number (001 to 030)
Computation channel number (A01 to A30)
p2ON
Records.
OFF
Does not record.
p3
1 to 6
timer number (recording interval:
Effective only when digital records are set for
“multiple”)
Example
Perform digital recording of channel 6 in slot 3 at the
interval of timer 2.
PD036, ON, 2
Comments
• The optional computation channel number for a
stand-alone model is A01 to A30.
PM
Turns on or off every channel of manual
printing.
Mode
Operation mode
Setting
PMp1, p2<terminator>
p1
Channel number (001 to 030)
Computation channel number (A01 to A30)
p2ON/OFF
Example
Perform manual printing for channel 6 in slot 3.
PM036, ON
Comments
• The optional computation channel number for a
stand-alone model is A01 to A30.
PA
Turns on or off the alarm printing for
every channel level.
Mode
Operation mode
Setting
PAp1, p2, p3, p4<terminator>
p1
Channel number (001 to 030)
Computation channel number (A01 to A30)
p2Level (1 to 4)
p3
OFF
No alarm printing
ON1
Printing when an alarm is generated
ON2Printing when an alarm is generated
or reset
p4
Selection of additional message
OFF
Does not print an additional message.
01 to 20
Message number
Example
When an alarm of level 2 of channel 6 in slot 3 is
generated, print the alarm and message No. 5.
PA036, 2, ON1, 05
Comments
• When an alarm is generated or reset, the alarm
generation time or alarm type is printed.
• If an additional message is specified, the message
set with the SG command is also printed.
• The optional computation channel number for a
stand-alone model is A01 to A30.
PC
Turns on or off scale printing for every
channel.
Mode
Operation mode
Setting
PCp1, p2<terminator>
p1
Channel number (001 to 030)
Computation channel number (A01 to A30)
p2OFF
No scale printing
ON1
Printing for every 20% of the scale
length
ON2Printing at 0% and 100% of the scale
length
ON3
Printing at 0%, 50%, and 100% of the
scale length
Example
Print the scale of channel 6 in slot 3 of subunit 4 at
positions 0%, 50% and 100%.
PC036, ON3
Comments
• For a channel for which recording is done in partially
expanded recording, the following applies regardless
of the p2 setting:
If the recording width is 100 mm or more, printing
is carried out at positions 0%, 100% and at a point
on the partially expanded recording boundary.
If the recording width is less than 100 mm but 50
mm or more, printing is carried out at positions 0%
and 100%.
If the recording width is less than 50 mm, printing
is not carried out.
• This is effective for analog recording channels.
• A channel whose recording width is less than 50
mm is not printed.
• If ON1 is set to a channel whose recording width is
less than 150 mm, the setting is invalid. Printing is
carried out at positions 0%, 50% and 100% only.
• If ON2 is set to a channel whose recording width is
less than 100 mm, the setting is invalid. Printing is
carried out at positions 0% and 100% only.
• The optional computation channel number for a
stand-alone model is A01 to A30.
5.3 Setting the Recording
Summary of Contents for DR130 SERIES
Page 39: ...4 9 Command Format 4 4 5 Input Range Parameter This page intentionally left blank ...
Page 40: ...4 10 4 5 Input Range Parameter This page intentionally left blank ...
Page 56: ...5 15 Commands 5 This page intentionally left blank 5 5 Other Settings ...