Operating manual
for the user
EPANA 6 kW
EN
3.1 Commissioning (requirements/preparation)
●
Please ensure that no objects made from flammable materials are
located or placed in the radiation range of the fireplace
(See chapter 2.6)!
●
Convection air openings may not be covered!
●
The precautions for the combustion air supply may not be modi-
fied. In particular, care must be taken to ensure that the necessary
combustion air lines are open during operation of the fireplace!
●
Conduct a visual inspection of the burner trough before every
start and clean the burner trough if necessary!
Fig. 3.1
keep the convection air openings clear
Fig. 3.2
Burner trough visual inspection
3.2 Filling with pellets
●
Open the cover of the pellet reservoir!
●
Fill the pellet reservoir with pellets! Use only pellets which comply
with DIN EN 14961-2 and the DIN-plus certification programme or
the Austrian standard M 7135!
●
When pouring in the pellets, take care to ensure that the sawdust
which may be present is not poured into the pellet reservoir!
max. 30 mm
max. 10 %
DIN EN 14961-2 / Zertifizierungsprogramm DIN-plus / Ö-Norm M 7135
max. 6 mm
Fig. 3.3
Only fill the pellet reservoir with permissible pellets
20 kg
ca. 14 h
6,0 kW
(5)
ca. 20 kg
Fig. 3.4
Filling with pellets / max./min. pellet consumption
Tip! Refill the pellets while the pellet fireplace is cold!
Warning! Risk of serious personal injury,
property damage and/or environmental damage!
●
The pellet fireplace may only be fired with pellets which
comply with DIN EN 14961-2 and the DIN-plus certification
programme or the Austrian standard M 7135: Max. moisture
10%, max. diameter 6 mm, max. length 30 mm!
●
Store pellets in a dry and dust-free location!
3 Operating manual (for the user)
42