Page: 45
Service Guide ML320/ML321
Chapter 3 Maintenance & Disassembly
3.2.05 Operator Panel Assembly
NOTE: The operator panel assembly and board for the Rev D units are NOT compatible with
the Rev A, B, and C operator panel assembly and board.
Perform these procedures first:
- 3.2.01 (
)
- 3.2.04 (
)
-
Release the claws (1) and remove the operator panel assembly (2) from the chassis
(3). As the operator panel assembly is removed, it must be detached from the connector
(4) on the control board (5).
- Release the eight claws (6) and remove the operator board (7) from the bezel (8).