Page: 124
Service Guide ML320/ML321
Chapter A Reference Charts
A.2.06 Filter Assembly - Rev A, B, C, and D
Function
This assembly is a protective feature. It also filters out unwanted line noise. Its fuse will open
when a fault occurs in the printhead drive circuit, the space motor drive circuit, or any of their
peripheral circuits. This prevents component failure.
Firmware
NONE
Fuses
F2 (also known as the AC fuse)
1.5 amp (120 V)
or
1.0 amp (220 / 240 V)
Jumpers
NONE
Sensors
NONE
Switches
NONE
Test Points
NONE