Page: 59
Service Guide ML320/ML321
Chapter 3 Maintenance & Disassembly
3.2.12 Indicator Assembly (Bail Bar Assembly)
Perform these procedures first:
- 3.2.01 (
)
- 3.2.04 (
)
- 3.2.05 (
)
- 3.2.06 (
)
- Use needle-nose pliers to remove the left bail arm spring (1).
- Release the claw (2) and detach the left bail arm (3) from the bail bar (4).
- Pull the left bail arm through the guide hole (5) in the chassis and remove the arm.
- Detach the bail bar from the right bail arm (6).
- Use needle-nose pliers to remove the right bail arm spring (7).
- Release the claw (8) and detach the right bail arm from the bail bar.
- Pull the right bail arm through the guide hole (9) in the chassis and remove the arm.