3-43
Unique Switch b:8 - Transmission
Switch
Initial
Setting
Adjust Usage/Comments
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
0
Factory use only
2
0
Factory use only
1
0
Factory use only
0
0
Transmission when disable to
detect first NSF in feeder
transmission.
0: Retry to detect NSF
1: Transmit with the standard
protocol
Determine the action when disable to detect first
NSF in feeder transmission.
Unique Switch b:9 --- Factory use only
Unique Switch c:0 - Reception
Switch
Initial
Setting
Adjust Usage/Comments
7
0
Factory use only
6
0
Factory use only
5
1
Factory use only
4
1
Transmit CED signal when
manual/remote receive
0: No
1: Yes
Determines if sending CED signal at on-hook
transfer.
3
1
Pseudo-ring start time
(seconds)
5 6 8 10
Sets the time the pseudo-ring begins after
answering an incoming call.
(Fax/Tel Ready or Tel/Fax Ready mode only.)
2
0
Switch 3: 0 0 1 1
Switch 2: 0 1 0 1
1
1
Factory use only
0
1
Factory use only
Summary of Contents for OKIOFFICE 1200
Page 1: ...OKIOFFICE 1200 1600 FIELD ENGINEERING MANUAL Version 2 0 11 June 2002...
Page 7: ...iv Packaging contents 6 22 Installation 6 22 Setting of the Paper Size 6 25...
Page 12: ...2 2 OKIOFFICE 1200 Interconnect Block Diagram 2 2 OKIOFFICE 1200 Connection Diagram 2 2...
Page 13: ...2 3 OKIOFFICE 1600 Interconnect Block Diagram 1 2 OKIOFFICE 1600 Connection Diagram 1 2...
Page 14: ...2 4 OKIOFFICE 1600 Interconnect Block Diagram 2 2 OKIOFFICE 1600 Connection Diagram 2 2...