3-12
Machine Parameter D:8
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 1
0 0
Slice level adjustment of
“Darker” in Grayscale.
(Only for OKIOFFICE 1200)
Switch 76543210
00000000 Darkest setting
00000001
00000010 Initial setting
00000011
00000100 Lightest setting
Machine Parameter D:9
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 1
0 0
Slice level adjustment of
“Dark” in Grayscale.
(Only for OKIOFFICE 1200)
Switch 76543210
00000000 Darkest setting
00000001
00000010 Initial setting
00000011
00000100 Lightest setting
Machine Parameter E:0
∼∼∼∼
E:9 --- Factory use only
Machine Parameter F:0
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 0
0 0
Adjustment of the scanning
stretching and squeezing for
ADF and FBS.
(Horizontal)
The plus setting stretch the
image data and the minus
setting squeeze it.
Each setting changes by
0.1%
Switch 76543210 Settings
01111111 12.7 % Maximum
:
00100000 3.2 %
:
00011000 2.4 %
:
00010000 1.6 %
:
00001000 0.8 %
:
00000000 Initial setting
:
10001000 -0.8 %
:
10010000 -1.6 %
:
10011000 -2.4 %
:
10100000 -3.2 %
:
10111000 -12.7 % Minimum
Summary of Contents for OKIOFFICE 1200
Page 1: ...OKIOFFICE 1200 1600 FIELD ENGINEERING MANUAL Version 2 0 11 June 2002...
Page 7: ...iv Packaging contents 6 22 Installation 6 22 Setting of the Paper Size 6 25...
Page 12: ...2 2 OKIOFFICE 1200 Interconnect Block Diagram 2 2 OKIOFFICE 1200 Connection Diagram 2 2...
Page 13: ...2 3 OKIOFFICE 1600 Interconnect Block Diagram 1 2 OKIOFFICE 1600 Connection Diagram 1 2...
Page 14: ...2 4 OKIOFFICE 1600 Interconnect Block Diagram 2 2 OKIOFFICE 1600 Connection Diagram 2 2...