3-22
Memory Switch B:1 - Transmission
Switch
Initial
Setting
Adjust Usage/Comments
7
0
The time between reception of CFR and transmission of data
When CFR and data overlap due to line echo, increase the interval between CFR
and data transmission using this switch.
6 1
250 ms 500 ms 750 ms 1000 ms
Switch 7 0 0 1 1
Switch 6 0 1 0 1
5
0
Interval between DCS and TCF
When FTT is received after DCS and TCF signals due to line echo, increase the
interval between DCS and TCF signals using this switch.
4 0
75 ms 300 ms 450 ms 600 ms
Switch 5 0 0 1 1
Switch 4 0 1 0 1
3 *
2
*
Output attenuation
See table below
1 *
0 *
Memory Switch B:1…Output attenuation
Switch -15
dB
-14
dB
-13
dB
-12
dB
-11
dB
-10
dB
-9
dB
-8
dB
-7
dB
-6
dB
-5
dB
-4
dB
-3
dB
-2
dB
-1
dB
-0
dB
3
1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
2
1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0
1
1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0
0
1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
↑
↑
Initial setting for OKIOFFICE 1600 Initial setting for OKIOFFICE 1200