6-23
5. Release the tab of the harness door under the machine, and then remove the harness door.
6. Put the machine on the second cassette.
7. Pass the harness and the ground wire of the second cassette through the harness door.
Then attach the ferrite core to the harness as illustration below.
8. Connect the harness to the connector (P17) on the Main control PCB.
9. Re-attach the shield plate using four mounting screws.
Note: You should attach the ground wire at the lower left corner of the shield plate using the screw,
as shown in the illustration.
Note: Be sure to ensure no wire is trapped when reattaching the shield plate.
Note: The harness and F.G. wire is not such long actually as illustration.
Summary of Contents for OKIOFFICE 1200
Page 1: ...OKIOFFICE 1200 1600 FIELD ENGINEERING MANUAL Version 2 0 11 June 2002...
Page 7: ...iv Packaging contents 6 22 Installation 6 22 Setting of the Paper Size 6 25...
Page 12: ...2 2 OKIOFFICE 1200 Interconnect Block Diagram 2 2 OKIOFFICE 1200 Connection Diagram 2 2...
Page 13: ...2 3 OKIOFFICE 1600 Interconnect Block Diagram 1 2 OKIOFFICE 1600 Connection Diagram 1 2...
Page 14: ...2 4 OKIOFFICE 1600 Interconnect Block Diagram 2 2 OKIOFFICE 1600 Connection Diagram 2 2...