3-10
Machine Parameter D:0
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 1
0 0
Slice level adjustment of
“Light” in the mode without
Grayscale.
(Only for OKIOFFICE 1200)
Switch 76543210
00000000 Darkest setting
00000001
00000010 Initial setting
00000011
00000100 Lightest setting
Machine Parameter D:1
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 1
0 0
Slice level adjustment of
“Lighter” in the mode without
Grayscale.
(Only for OKIOFFICE 1200)
Switch 76543210
00000000 Darkest setting
00000001
00000010 Initial setting
00000011
00000100 Lightest setting
Machine Parameter D:2
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 1
0 0
Slice level adjustment of
“Normal” in the mode without
Grayscale.
(Only for OKIOFFICE 1200)
Switch 76543210
00000000 Darkest setting
00000001
00000010 Initial setting
00000011
00000100 Lightest setting
Machine Parameter D:3
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 1
0 0
Slice level adjustment of
“Darker” in the mode without
Grayscale.
(Only for OKIOFFICE 1200)
Switch 76543210
00000000 Darkest setting
00000001
00000010 Initial setting
00000011
00000100 Lightest setting
Summary of Contents for OKIOFFICE 1200
Page 1: ...OKIOFFICE 1200 1600 FIELD ENGINEERING MANUAL Version 2 0 11 June 2002...
Page 7: ...iv Packaging contents 6 22 Installation 6 22 Setting of the Paper Size 6 25...
Page 12: ...2 2 OKIOFFICE 1200 Interconnect Block Diagram 2 2 OKIOFFICE 1200 Connection Diagram 2 2...
Page 13: ...2 3 OKIOFFICE 1600 Interconnect Block Diagram 1 2 OKIOFFICE 1600 Connection Diagram 1 2...
Page 14: ...2 4 OKIOFFICE 1600 Interconnect Block Diagram 2 2 OKIOFFICE 1600 Connection Diagram 2 2...