2-16
2.8.6 Fusing
An Overview
The toner image transferred on to the paper is securely fixed.
A heat roller system is used as the fusing system. The toner image is fused by Heater Roller heated
by the Heater Lamp, and securely fixed by the pressure between the Heater roller and Press rollers.
A Thermistor detects and controls the Heater Roller temperature.
The Thermostat functions when the Heater Lamp is not turned OFF even if the Thermistor detects a
high temperature malfunction.
Fusing Temperature Control Circuit
The Thermistor detects the surface temperature of the Heater Roller and inputs that analog voltage
into the Main Control PCB. Corresponding to this data, the Heater Lamp ON/OFF signal is output to
the Heater ON/OFF switch of the power supply unit, causing the Heater Lamp to turn ON or OFF to
control the fusing temperature.
When the Heater Lamp is not turned OFF even if the Thermistor detects a high temperature
malfunction, the thermostat shuts down the power to the heater lamp. When the thermostat is
malfunction, the thermal cut-off shuts down the power to the heater lamp.
L
N
Main Control PCB
Fusing temperture
control circuit
Power supply unit
AC Inlet
Fusing unit
Thermistor
Heater Lamp
Thermostat
Thermal cut-off
Heater
on/off
switch
Main switch
Summary of Contents for OKIOFFICE 1200
Page 1: ...OKIOFFICE 1200 1600 FIELD ENGINEERING MANUAL Version 2 0 11 June 2002...
Page 7: ...iv Packaging contents 6 22 Installation 6 22 Setting of the Paper Size 6 25...
Page 12: ...2 2 OKIOFFICE 1200 Interconnect Block Diagram 2 2 OKIOFFICE 1200 Connection Diagram 2 2...
Page 13: ...2 3 OKIOFFICE 1600 Interconnect Block Diagram 1 2 OKIOFFICE 1600 Connection Diagram 1 2...
Page 14: ...2 4 OKIOFFICE 1600 Interconnect Block Diagram 2 2 OKIOFFICE 1600 Connection Diagram 2 2...