3-3
Machine Parameter A:0
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 0
0 0
Country code
The country code enables the ROM to output the
correct programming information for the respective
country.
Machine Parameter A:1
Switch
Initial
Setting
Adjust Usage/Comments
7 0
Non-loaded
cable
compensation (TX)
0: 0: 1: 1:
0 db 4 db 8 db 12 db
6
1
0: 1: 0: 1:
5 0
Non-loaded
cable
compensation (RX)
0: 0: 1: 1:
0 db 4 db 8 db 12 db
4
1
0: 1: 0: 1:
3 *
2 *
1 *
0 *
Output attenuation
See table below
Note: The setting of this switch is available only
when setting other than 0 dB and this setting is
used instead of Memory Switch B:1, bit 3-0.
Machine Parameter A:1…Output attenuation
Switch -15
dB
-14
dB
-13
dB
-12
dB
-11
dB
-10
dB
-9
dB
-8
dB
-7
dB
-6
dB
-5
dB
-4
dB
-3
dB
-2
dB
-1
dB
-0
dB
3
1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
2
1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0
1
1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0
0
1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
Summary of Contents for OKIOFFICE 1200
Page 1: ...OKIOFFICE 1200 1600 FIELD ENGINEERING MANUAL Version 2 0 11 June 2002...
Page 7: ...iv Packaging contents 6 22 Installation 6 22 Setting of the Paper Size 6 25...
Page 12: ...2 2 OKIOFFICE 1200 Interconnect Block Diagram 2 2 OKIOFFICE 1200 Connection Diagram 2 2...
Page 13: ...2 3 OKIOFFICE 1600 Interconnect Block Diagram 1 2 OKIOFFICE 1600 Connection Diagram 1 2...
Page 14: ...2 4 OKIOFFICE 1600 Interconnect Block Diagram 2 2 OKIOFFICE 1600 Connection Diagram 2 2...