5-34
7. Loosen the REAR ANGLE mounting screw.
Remove three FBS MOTOR BRACKET mounting screws.
Remove the BELT.
Remove the FBS MOTOR with the bracket.
Rear angle
FBS motor brackect
FBS Motor
SCANNER ASSEMBLY
1. Remove the TOP FRONT COVER, THE TOP RIGHT COVER and the TOP LEFT COVER.
2. Remove the BOTTOM CORNER COVER.
3. Remove the HINGE SCREW and the HARNESS HOLDER mounting screw, and then remove the
PLATEN COVER Assembly.
4. Remove the TOP REAR COVER.
5. Remove the GROUND PLATE mounting screw, and then remove the GROUND PLATE.
Ground plate