![Oki ML7065-033 User Manual Download Page 60](http://html1.mh-extra.com/html/oki/ml7065-033/ml7065-033_user-manual_3624632060.webp)
ML7065-033 User’s Manual
Chapter 7 Commands
54
3) MLME-SET.REQUEST: Promiscuous mode
SCI header
Payload
LSB
MSB
Field name
Request
Length
Primitive
Code
PIBAttribute PIBAttributeValue
Code 0x02
0x03
0x5B
0x51
0x01
MLME-SET.CONFIRM
SCI header
Payload
LSB
MSB
Field name
Status
Length
Primitive
Code
status PIBAttribute
Code 0x03
0x03
0x5C
0x00
0x51
The following data will be outputted when beacons are received after non-discriminating mode is turned on.
MLME-DATA.INDICATION
SCI header
Payload
LSB
MSB
Field name
Status
Length
Primitive
Code
Receive MAC frame
Code 0x03
0x0F
0x42
0x00-0x80-0x96-0x54-0x43-0x43-0x6F-0x33-0xCF-0x00
-0x00-0x14-0x96-0xF9