20
Scan Position Adjustment
Side registration adjustment - The separate setting items are prepared for FBS, ADF
(front side) and ADF (back side) independently.
Setting for Flat Bed Scanning (FBS)
Perform adjustment so that the scan start position in the horizontal scanning direction
during
FBS Scanning
stays within the reference value. Adjustment in increments of 1
item (5/600 dpi = 0.2117 mm) is possible in this setting. When a value is added in the
negative (-) direction, the scan image on a PC moves to the right. When a value is added
in the positive (+) direction, the scan image on a PC moves to the left.
Setting for ADF (front side)
Perform adjustment so that the scan start position in the horizontal scanning direction
during ADF front side scanning stays within the reference value. Adjustment in
increments of 1 item (5/600 dpi = 0.2117 mm) is possible in this setting. When a value is
added in the negative (-) direction, the scan image on a PC moves to the left. When a
value is added in the positive (+) direction, the scan image on a PC moves to the right.
Setting for ADF (rear side)
Perform adjustment so that the scan start position in the horizontal scanning direction
during ADF rear side scanning stays within the reference value. Adjustment in
increments of 1 item (5/600 dpi = 0.2117 mm) is possible in this setting. When a value is
added in the negative (-) direction, the scan image on a PC moves to the left. When a
value is added in the positive (+) direction, the scan image on a PC moves to the right.
Top End Position Adjustment
Perform adjustment so that the scan start position in the vertical scanning direction during
FBS
scanning stays within the reference value. If shade is scanned at the top end of a
document, make adjustment in the positive direction. If deficiency occurs at the top end
of a document, make adjustment in the negative direction. Adjustment in increments of 1
item (0.1408 mm) is possible in this setting. When a value is added in the negative (-)
direction, the scan image on a PC moves down. When a value is added in the positive (+)
direction, the scan image on a PC moves up.
Setting for ADF (front side)
Perform adjustment so that the scan start position in the vertical scanning direction during
ADF front side scanning stays within the reference value. If shade is scanned at the top
end of a document, make adjustment in the positive direction. If deficiency occurs at the
top end of a document, make adjustment in the negative direction. Adjustment in
increments of 1 item (0.0619 mm) is possible in this setting. When a value is added in the
negative (-) direction, the scan image on a PC moves down. When a value is added in the
positive (+) direction, the scan image on a PC moves up.
Setting for ADF (back side)
Perform adjustment so that the scan start position in the vertical scanning direction during
ADF rear side scanning stays within the reference value. If shade is scanned at the top
end of a document, make adjustment in the positive direction. If deficiency occurs at the
top end of a document, make adjustment in the negative direction. Adjustment in
increments of 1 item (0.0619 mm) is possible in this setting. When a value is added in the
negative (-) direction, the scan image on a PC moves down. When a value is added in the
positive (+) direction, the scan image on a PC moves up.