Monitoring Printer Environmental Conditions
The following printer environmental conditions can be monitored during generation of
test prints.
The following messages are displayed during test print.
P *** =
Number of test prints (unit: sheet)
W*** =
Print wait time (unit: sheet)
Pressing the
(2) key
switches the display. When the
(#)
key is pressed, the screen exits
the test. (Screen returns to the item 1 condition.)
T =*** =
Environment temperature measurement value [unit: °C]
U =*** =
Upper heater temperature measurement value. [unit: °C]
[###] =
target temperature [unit: °C]
H =***% =
Environment humidity measurement value [unit: %]
L = *** =
Lower thermistor measurement value. [unit: °C]
[###]
= Lower thermistor AD value [unit: HEX]
Pressing the
(2) key
switches the display. When the
(#)
key is pressed, the screen exits
the test. (Screen returns to the item 1 condition.)
KTR, YTR, MTR and CTR are the transfer voltage setting values for each color. (measured in KV)
Pressing the
(2) key
switches the display. When the
(#)
key is pressed, the screen exits
the test. (Screen returns to the item 1 condition.)
KR, YR, MR, CR are transfer roller resistance values for each color. [measured in
μ
A]
Pressing the
(2) key
switches the display. When the
(#)
key is pressed, the screen exits
the test. (Screen returns to the item 1 condition.)
ETMP: Hopping motor standard speed correction parameter (Environment temperature) [unit: DEC]