<< When
DENS ADJ EXECUTE
is executed >>
•
The Density error correction test is executed. (The
[ON LINE]
lamp blinks.)
•
When the test is complete, the test result (OK or error name) is displayed in the
upper column of the display window and
**** RESULT
is displayed in the lower
column of the display window.
When the
(2) key
is pressed, test results are incremented and displayed in order.
When the
(8) key
is pressed, test results are decremented and displayed in order.
When the
(4) key
is pressed, screen returns to the item 2 status.
•
When the
(#) key
is pressed while the test in progress, the test is interrupted (the
[ON LINE]
lamp lights) and screen returns to the item 2 status.
•
<< When
DENS ADJ RESULT
is executed >>
The key operations are the same as those above.
<< When
DENS ADJ PAR-SET
is executed >>
The message is displayed but does not function.
<<
AUTO CALIBRATION
is executed >>
•
Automatic setting of the density sensor sensitivity correction value is executed.
(The
[ON LINE]
lamp blinks.)
•
When the test is complete, the test result (OK or error name) is displayed in the
upper column of the display window and
**** RESULT
is displayed in the lower
column of the display window.
When the
(4) key
is pressed, screen returns to the item 2 status.
When the
(#) key
is pressed while the test in progress, the test is interrupted (the [ON
LINE] lamp lights) and screen returns to the item2 status.
When the
(4) key
is pressed, the screen exits the test. (Screen returns to the item 1 condition.)
Display Details
DENS ADJ EXECUTE
Execution of density correction
DENS ADJ PAR-SET
The message is displayed but does not
function.
DENS ADJ RESULT
Referring to the result of density correction
AUTO CALIBRATION
Automatic setting of density sensor
sensitivity correction value
41