45641001TH Rev.1
11-56 /
Oki Data CONFIDENTIAL
05/
08
Mode
Element
Sub
element
Item
Subitem
Code Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce-
dure
08
Setting
mode
System
9060
Destination
display at SRAM
initialization
Refer to
contents
0-255
SYS
20: ODA (ODC-IT) 21: OEL (ODC-IT)
22: AOS (ODC- IT) 23: JP (ODC-IT) 30: ODA (ODC-OA)
31: OEL (ODC-OA) 32: AOS (ODC-OA)
33: JP (ODC-OA)
<Default value>
ODA: 20 OEL: 21 AOS: 22 JP: 23
* When the default value of 08-9845 is “0”, the default value
of this code is “ODA: 30 OEL: 31 AOS: 32 JP: 33”.
2
08
Setting
Mode
System
HDD
9065
HDD diagnostic
menu display
-
-
SYS Displays the HDD information.
2
08
Setting
Mode
System
HDD
9072
Performing HDD
testing
-
-
SYS Checks the bad sector. It may take more than 30 minutes
to finish the checking.
3
08
Setting
mode
System
General
9081
Initialization
of department
management
information
-
-
SYS Initializing of the department management information
Enter the code with the digital keys and press the
[INITIALIZE] button to perform the initialization.
If the area storing the department management
information is destroyed for some reason, “Enter
Department Code” is displayed on the control panel even
if the department management function is not set on. In
this case, initialize the area with this code. This area is
normally initialized at the factory.
3
08
Setting
Mode
System
Initialization
9083
Initialization of NIC
information
-
-
SYS Returns the value to the factory shipping default value.
3
08
Setting
mode
System
General
9100
Date and time
setting
-
13 digits
-
Year/month/date/day/hour/minute/second
Example:
03 07 01 3 13 27 48
“Day” - “0” is for “Sunday”. Proceeds Monday through
Saturday from “1” to “6”.
5
08
Setting
mode
System
User
interface
9102
Date display format Refer to
contents
0-2
SYS 0: YYYY.MM.DD
1: DD.MM.YYYY
2: MM.DD.YYYY
<Default value>
ODA: 2
JP: 0
Others: 1
1