131
Maintenance
K Cleaning around the ionizers and the sensors for automatic print adjustment
Ink may adhere to the area around the ionizers and to the sensors for automatic print adjustment due to the effect
of the ions generated by the ionizers. Periodic cleaning is required because this may cause a loss of precision of
the automatic print adjustment function and ink particles to fall onto the printout. The amount of ink that adheres
to these areas varies depending on the print data and the ionizer usage, but it is recommended to clean the area
approximately once per year.
1
PRINTER READY
01: PAPER / 1626mm
Press the
MAINTENANCE
button.
2
MAINTENANCE
2
START MAINTENANCE
Press the
Down
button to select
PH
MAINTENANCE
.
3
MAINTENANCE
2
PH MAINTENANCE
Press the
OK
button.
4
>PH MAINTENANCE
2
SET PH FOR CHECK
,
Press the
Down
button to select
SET PH FOR
CHECK
, and then press the
OK
button.
5
>>SET PH FOR CHECK
OK?
Press the
OK
button.
6
CARRIAGE IS MOVING
PLEASE WAIT
Carriage stops moving.
The carriage moves to the maintenance area.
The printer issues a warning beep.
When the carriage moves, the printer issues a
warning beep.
To disable the warning beep, see the