43605601TH Rev.1
74 /
Oki Data CONFIDENTIAL
4.2.3.9 OP frame assembly
(1) Open the top cover.
(2) Open the front cover.
(3) Remove the right side cover (See Subsection 4.2.2)
(4) Remove the plate shield front and cable (See Subsection 4.2.16)
(5) Detach FFC which connects the control panel assembly with the control panel PCB.
(6) Remove the four screws (silver) and then detach the OP frame assembly
while pushing
the side cover outward
. (Tool No.1)
Figure 4-2-3-9 OP frame assembly