Oki Data CONFIDENTIAL
43605601TH Rev. 1
174 /
7.5.2.(2) Irregular Operation of the device after turning on the power
(2-1) No operation
Confirmation Items
Confirmation Tasks
Action at NG
(2-1-1) Peripheral check of power supply
AC power supply supplied to the
printer.
Confirm the supplied voltage of the
AC power supply.
Supply the AC power supply.
Voltage setting of low-voltage power
supply unit (/230V 100V).
Measurement of the supplied AC
voltage. Confirm the power supply
setting of the equipment used.
(Confirm the short plug of low-
voltage supply setting switch. Short
plug Have/None=100V /230)
Adjust the low-voltage power supply
setting.
The 5V power supply and 24V
power supply and 30V power supply
supplied to the main board (M32
PCB).
Confirm the power supply by the
POW connector of the main board
(M32 PCB).
1, 2 pin:0VP
3 pin: 0VU
4 pin: +30V
5, 6 pin:+24V
7, 8, 9, 10 pin:+5V
11~15 pin:0VL
Exchange low-voltage power supply.
Summary of Contents for C3530n MFP
Page 1: ...Oki Data CONFIDENTIAL C3530nMFP Maintenance Manual 032807A ...
Page 8: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 ...
Page 50: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 50 Sample In case of C3530MFP 2 ...
Page 108: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 108 ...
Page 109: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 109 ...
Page 220: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 220 ...
Page 221: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 221 ...
Page 229: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 229 229 Solder side ...
Page 230: ...Please refer to the Illustrated Parts Manual for spare part information ...