Oki Data CONFIDENTIAL
43605601TH Rev. 1
176 /
(2-3) Abnormal odor
(2-4) Slow starting time
When insert the jig, please insert it into the gap of the phosphor bronze terminal that can be
seen inside the ID unit side cover.
Treatment device(43291601PP)
Confirmation Items
Confirmation Tasks
Action at NG
(2-3-1) Locate the position with abnormal odor occurred.
Fuser unit
Take out the fuser and confirm the odor.
Perform (2-3-2).
Low-voltage power supply
unit
Take out the low-voltage power supply unit and
confirm the odor.
Exchange low-
voltage power
supply unit
(2-3-2) Check the condition of fuser.
Life count of fuser
Confirm the life count of the fuser by the maintenance
utility.
It may have
abnormal smell
around a new printer.
Foreign confirmation of
fuser
Confirm whether the fuser is jammed with foreign
body such as paper inside.
Remove the foreign
body.
Confirmation Items
Confirmation Tasks
Action at NG
(2-4-1) Check a fuser unit
Halogen lamp
Confirm the wattage of the halogen lamp mounted in
the fuser.
Exchange for
wattage parts of the
rated voltage.
(2-4-2) Check optional parts
Expansion memory
Reset the optional parts (expansion memory) and
recheck the operation.
Exchange optional
parts
Summary of Contents for C3530n MFP
Page 1: ...Oki Data CONFIDENTIAL C3530nMFP Maintenance Manual 032807A ...
Page 8: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 ...
Page 50: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 50 Sample In case of C3530MFP 2 ...
Page 108: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 108 ...
Page 109: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 109 ...
Page 220: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 220 ...
Page 221: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 221 ...
Page 229: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 229 229 Solder side ...
Page 230: ...Please refer to the Illustrated Parts Manual for spare part information ...