43605601TH Rev.1
70 /
Oki Data CONFIDENTIAL
4.2.3.5 Top cover assembly
(1) Remove the scanner. (See 4.2.1)
(2) Open the top cover.
(3) Remove the left side cover. (See Subsection 4.2.3.1)
(4) Remove the right side cover. (See Subsection 4.2.3.2)
(5) Remove the rear cover. (See Subsection 4.2.3.3)
(6) Remove the plate heat. (See Subsection 4.2.3.18)
(7) Remove the plate shield front. (See Subsection 4.2.3.16)
(8) Remove a screw (silver)
.
(9) Remove the M32-PCB (main board) (See Subsection 4.2.3.23), and then, remove the head
cable (FFC) and the RFID cable.
(10) Remove two E-type retaining rings two sprint torsions and the top cover assembly
.
Figure 4-2-3-5 Top cover assembly
ViewA
ViewA
RFID
K
Y
M
C
Head cable(FFC)
BLA-PCB
(Main circuit board PCB)