4.2.2.6
Removing ADF Assembly
(1) Remove the two screws(black)
to remove the base stopper
upward at an angle.
(2) Reverse the scanner and put the stays L and R upright.
(3) Remove the six screws(black)
and then the MPCBA cover
.
(4) Unfix the ground wire by removing the screw(black).
(5) Remove the ADF connector.
(6) Unthread the cable through its guide groove.