4.2 Part replacement methods
This subsection explains the replacement methods for the parts and assemblies illustrated in
the disassembly system diagram below.
4.2.1 Detachment methods of the scanner and printer
(1) By lifting the scanner in the direction of the arrow, create screw removal space above the
printer.
(2) Remove the four screws(silver-colored)
(hold the front side of the stay on each side of the printer so as not to allow the scanner to tilt
back).
(3) Put the scanner back in its original horizontal position.
(4) By holding the scanner by the right and left stays and vertically lifting it up, separate the
scanner from the printer.
Note: When attaching the scanner to the printer, bring down the scanner onto the printer
from directly above the printer so as not to damage the connector joints.