Oki Data CONFIDENTIAL
43605601TH Rev. 1
202 /
7.5.2.(15) Dew Condensation Errors (Service call 123)
(15-1) Dew Condensation
Confirmation Items
Confirmation Tasks
Action at NG
(15-1-1) Check of the connection
Connection of main board
(BLA PCB) and high-
voltage board
Check whether 12-pole FFC is normally connected
with the HVOLT connector of main board (M32 PCB).
Check whether 12-pole FFC is normally connected
with the CN1 connector of high-voltage board.Check
whether incompletely connection and oblique insertion
occurs.
Reinsert the cable
normally.
Connection of main board
(BLA PCB) and high-
voltage board
Check the wire-break by tester. By visual inspection,
check whether peeling off of coating occurs.
Replace FFC with a
new one.
(15-1-2) Environment condition
Extreme change of
environment condition
Is environment temperature changed from low to high
in a short time?(For example, move from cold storage
area to office environment.)
After moving the
printer to the new
environment for
about one hour till
it adapts to new
environment, turn
on the printer again.
Before turning
on the printer,
please check the
temperature of
sheet metal of rear
control panel and
inner sheet metal
by hand and check
that the difference
between the
above and room
temperature doesn’
t exist, then turn on
again.
Summary of Contents for C3530n MFP
Page 1: ...Oki Data CONFIDENTIAL C3530nMFP Maintenance Manual 032807A ...
Page 8: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 ...
Page 50: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 50 Sample In case of C3530MFP 2 ...
Page 108: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 108 ...
Page 109: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 109 ...
Page 220: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 220 ...
Page 221: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 221 ...
Page 229: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 229 229 Solder side ...
Page 230: ...Please refer to the Illustrated Parts Manual for spare part information ...