4.2.2.3 Removing ADF PCBA
(1) Gently open the ADF top cover.
(2) Remove the two screws(black)
to remove the cover-gear
.
(3) Remove the two screws(black)
.
(4) Turn the lever
in the direction of the arrow to put the frame Assembly
and the paper tray
upright.
(5) Remove the two screws(black)
.
(6) Restore the frame Assembly
and the paper tray
in their original positions.
(7) Release the frame Assembly
from the hook near its support point on each side of the
scanner to remove the Assembly and the paper tray
.
(8) Remove the two screws(black)
to remove the ground wire
.
(9) Unplug all the connectors and remove the ADF PCBA
.