Oki Data CONFIDENTIAL
43605601TH Rev. 1
167 /
Table 7-1-2 service call error list (3/6)
Display
Cause
Details of error
Method
Service call
155: Error
Defective fuse
cutting of fuser
Is the fuser installed correctly?
Does the error recur?
No
Yes
Yes
Reinstall the fuser after its
connection connector is cleaned
Turn on the power supply again
Replace M32 board after check
the cable connection.
Service call
160: Error
163: Error
Defective toner
sensor detection.
It does not occur
during shipping
setting
Is the toner cartridge installed?
Is the lock level of toner set?
Does the error recur?
Does the error recur?
Does the error recur?
No
No
Yes
Yes
Yes
Install a toner cartridge.
Turn the lock lever of toner
cartridge to the fixed position.
Remove the right side cover, take
measures to prevent the right
side of the device from being
exposed to ambient light, and
confirm that the toner sensor is
lighted during initialization of the
device.
Reconfirm it after replacing the
toner sensor Assy.
Replace the M32 board.
Service call
167: Error
Thermistor
Slope Error
Is the error message displayed?
Does the error recur?
Yes
Yes
Turn on the power supply again
Turn on the power supply again
after storage for 30 minutes.
Service call
168: Error
Compensation.
Thermistor Error
Is the error message displayed?
Does the error recur?
Yes
Yes
Turn on the power supply again
Turn on the power supply again
after storage for 30 minutes.
Note)
Service call
169: Error
Upper Side
Thermistor Error
Is the error message displayed?
Does the error recur?
Yes
Yes
Turn on the power supply again
Turn on the power supply again
after storage for 30 minutes.
Service call
170: Error
171: Error
Thermistor Short
circuit / Open
circuit of the fuser
is detected
Does the error recur?
Yes
Check the cable connection
between the ZAK board and M32
board and turn on the power
again.
Replace the fuser unit.
Replace the M32 board.
See Note.
Service call
172: Error
173: Error
Thermistor
Temperature
abnormality (high
or low) of the
fuser is detected Does the error recur?
Yes
Check the cable connection
between the ZAK board and M32
board and turn on the power
again.
Replace the fuser unit.
Replace the M32 board.
Service call
174: Error
The short circuit
of the backup
roller.
Thermistor is
detected. (For the
high temperature)
Does the error recur?
Yes
Check the cable connection
between the ZAK board and M32
board and turn on the power
again.
Replace the fuser unit.
Replace the M32 board.
Service call
175: Error
The open circuit
of the backup
roller.
Thermistor is
detected. (For the
low temperature)
Does the error recur?
Yes
Check the cable connection
between the ZAK board and M32
board and turn on the power
again.
Replace the fuser unit.
Replace the M32 board.
See Note.
Service call
176: Error
177: Error
Temperature
abnormality (high
or low) of the
backup
Laura thermistor
was detected
Does it become an error again?
Yes
Check the cable connection
between the ZAK board and M32
board and turn on the power
again.
Replace the fuser unit.
Replace the M32 board
Summary of Contents for C3530n MFP
Page 1: ...Oki Data CONFIDENTIAL C3530nMFP Maintenance Manual 032807A ...
Page 8: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 ...
Page 50: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 50 Sample In case of C3530MFP 2 ...
Page 108: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 108 ...
Page 109: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 109 ...
Page 220: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 220 ...
Page 221: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 221 ...
Page 229: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 229 229 Solder side ...
Page 230: ...Please refer to the Illustrated Parts Manual for spare part information ...