Service call
190: Error
Service call
200: Error
202: Error
Service call
209:
Down Load
Error
Service call
203: Error
204: Error
207: Error
208: Error
213: Error
214: Error
F0C: Error
FFE: Error
FFF: Error
Service call
230: Error
Service call
231: Error
Service call
240: Error
Service call
905: Error
906: Error
Service call
907: Error
Display
Cause
Details of error
Method
System memory
overflow
PU Firmware
Download Error
Custom Media
Type table
download failure
CU program
trouble
(203~214 are
not generated in
usual operation)
RFID Reader
not Installed
RFID Reader I/F
Error
Engine Program
Memory Error
Short circuit
error of the
Frame
thermistor
(thermistor
defect) is
detected
High
temperature
error of the
frame thermistor
(over 150)is
detected
Does the error recur?
Error occurs when the PU
firmware is rewritten
Failed in downloarding
Custom Media Type Table
Incorrect processing is performed
by the CU program.
Does the error recur?
RFID Reader Device error
Does the error recur?
An interface error was detected
with the RFID reader device.
01: communication error between
the RFID reader and the engine
PCB.
02: the transceiver circuit error of
the RFID reader.
03: communication error between
the RFID reader and the Tag chip.
04: the RFID Tag detection error
(more than 4chips).
240: Flash Memory
Hardware Error
Does the error recur?
Does the error recur?
Turn on the power supply again.
Install an additional RAM DIMM.
After the power supply is turned
on again, try to download again.
(Because this processing is not
performed during usual
operation, it does not occur.)
After the power supply is turned
on again, try to download again.
(Because this processing is not
performed during usual
operation, it does not occur.)
Turn on the power supply again.
Replace BLA board.
Check the connection of the
LUM board (RFID reader/writer
board).
Replace the LUM board (RFID
reader/writer board).
Replace the BLA board.
01: Same as Error 230.
02: Replace the LUM board
(RFID reader/writer board).
03: Check the connection of the
antenna cable.
04: Check if the number of RFID
Tags is correct.
If the error occurs again after re-
turning on the power supply,
replace the board of the unit.
Check the cable connection
between the ZAK board and
BLA board and turn on the
power again.
Replace the fuser unit.
Replace the BLA board.
Check the cable connection
between the ZAK board and
BLA board and turn on the
power again. Replace the fuser
unit.
Replace the BLA board.