Oki Data CONFIDENTIAL
43163501TH Rev. 1
99 /
• CU serial number is shown in the Printer Serial Number Column in the header of Status
Page. Therefore, the confirmation of the CU serial number after the change can be done
by printing the Status Page.
• The PU serial number is shown in the Lot Number: column of the last line which is in the
header of the MenuMap.
(2) [When not facing OEL]
(2-1) Set the PU serial number
(Maintenance utility operation manual, Section 2.4.1.2, PU circuit board setting)
SAP serial number can be applied to the device. The SAP serial number is displayed
in the highest rung of the serial number label. It is a 12-digit number including production
place (2 digits), production year (2 digits), sequence number (6 digits) and revision
number (2 digits).
• PU serial number is a 10-digit number which is basically the same as SAP serial number
except that it has no the 2-digit revision number.
• Set on the menu of [Section 2.4.1.1.2.1, PU serial number setting] of [Section 2.4.1.1.2
PU circuit board setting function].
• If you want to specify the PU serial number, please add a “0” (a normal-width zero) then
input the 11-digit number. (Please notice that when read out, the number will be 10
digits.)
As shown in the following image, on the menu of [PU serial number setting], eliminate
the 2-digit revision number then add a normal-width zero to the 10-digit number and
input it.
Add one-byte 0 to the top of 10-digit figure of 12-digit SAP serial number to set.
Set "0AE01234567" in the setting screen of PU serial number.
Revision
A
B
C
Made in
A E 0 1 2 3 4 5 6 7 8 9
Figure of Serial No. label image
• PU serial number will be output to the Printer Serial Number column in the header of
Status Page. For this reason, check of PU serial number is performed by printing
Status Page.
• After the configuration in the UK factory, when facing OEL, the PU serial number is
taken as Lot Number and shown in the Lot Number: column of the last line which is in
the header of the Status Page.
(2-2) Set the CU serial number
CU serial numbe setting is unnecessary When not facing OEL.