![OHAUS Defender 5000 TD52P Service Manual Download Page 49](http://html1.mh-extra.com/html/ohaus/defender-5000-td52p/defender-5000-td52p_service-manual_3547605049.webp)
45
Defender 5000 Indicators Service Manual
APPENDIX A. CONFIGURING THE MAIN PCBA
Note:
To perform the configuration, the RS232 option (PN: 30101019) needs to be installed on the
indicator. Once installed, connect the cable between indicator and computer.
Once a new Main PCBA is installed one will need to configure the new Main PCBA according to their
region.
1.
Down load and install OHAUS Service and Repair Tools (Version 2.2.0.0 and later).
2.
Open the software and select 'Repair Tool' and click 'Next'
3.
Select 'TD52' under Product Selection and click 'Next'.
4.
Select 'Replace Main PCB', click 'Next'
5.
Set the same protocol setting between indicator and computer and click 'Next'.
6.
Input the 'Serial Number' and 'Model Number' , Select the 'Shipping Country' from the location list
and click 'Next'.
7.