SET TISSUE LOADING BAR GRAPH (TLBG) ALARM
Information includes (Fig. 55):
> Graphic TLBG
> TLBG Set Point (segments), flashing.
• Pressing and releasing the S button momentarily (< 2 sec-
onds) will decrease the Set Point from All 5 segments (Deco)
to 1 in increments of 1 segment.
• Depressing and holding the S button will scroll through the
Set Points at a rate of 4 Set Points per second until it is
released.
• Pressing and releasing the A button momentarily (< 2 sec-
onds) will save the setting and/or advance to the SET DIVE
TIME REMAINING (DTR) ALARM screen with the Set Point
flashing.
• Pressing and releasing the A button momentarily and repeat-
edly (< 2 seconds each time) will step through the other SET A
screens.
• Depressing the A and S buttons simultaneously for 2 seconds
will save the setting and revert back to the SET A screen.
• Depressing and holding the M button for 2 seconds will revert
to the Surface Mode screen.
• If no button is pressed during a period of 2 minutes, the unit
will revert to the Surface Mode screen.
Fig. 55 - Set TLBG Alarm
Setting the TLBG
Alarm to activate
before it enters the
DECO is highly
recommended.