134
ATOM (Watch) Battery Installation
• Slide a new 3 volt type CR2430 Lithium Battery, negative (-)
side down into the Battery Cavity. Slide it in from the Left
side (Fig. 121) and ensure that it slides under the contact clip
on the lower/right rim of the cavity.
• Lightly lubricate the new Hatch O-ring with silicone grease
and place it on the inner rim of the Battery Hatch. Ensure that
it is evenly seated (Fig. 122).
NOTE: The O-ring must be a genuine Oceanic
part that can be purchased from an Authorized
Oceanic Dealer. Use of any other O-ring will
void the warranty.
• Carefully place the Battery Hatch (with O-ring) into position
on the rim of the Battery Compartment, then press it evenly
and completely down into place.
• Maintain the Battery Hatch securely in place and turn it
counter clockwise 10 degrees using the special Battery Hatch
tool provided (Fig. 123A), or by pushing the lower portion to
the right while pushing the upper portion to the left (Fig.
123B).
Fig. 121 - ATOM Battery
Installation
Fig. 122 - ATOM Battery
Hatch O-ring Orientation
Fig. 123A - ATOM Battery
Hatch Installation
Fig. 123B - Alternate Battery
Hatch Installation