111
If PO2 continues to increase, the value displayed will increase
toward a maximum value of 5.00 ATA in increments of .01 ATA.
High PO2 Alarm
(Fig. 103)
When PO2 reaches a value of 1.60 ATA, or the PO2 Alarm Set
Point (a user setting), the red LED warning light will flash, the
Audible Alarm will sound (unless set OFF), and the current PO2
value, graphic PO2, and UP Arrow will flash as a warning until
PO2 decreases.
The graphic message UP > HIGH > PO2 will continue to scroll,
and the Bar Graph, Transmitter Link icon, Current Depth, and
Dive Time Remaining will be displayed.
• Press the S button to acknowledge/silence the alarms.
• Press the A button to view the Alternate #1 (Air Time Remaining and Tank Pressure,
Alternate #2 (O2 data), and Secondary (Temperature/Time) Displays.
• The unit will revert to the Main (Default) Display after 3 seconds.
• Press the L button to activate the Backlight.
HIGH OXYGEN ACCUMULATION
The O2 Bar Graph displays either oxygen accumulated during that nitrox dive, or during
the repetitive nitrox dives you conduct during that 24 hour period, whichever of the two is
greater at that time. The O2 Bar Graph offers you a convenient way to monitor how close
you are coming to the limits of oxygen exposure.
Use it as a visual reference to
place a wider margin of protection between you and the Limits.
Fig. 103 - High PO2 Alarm
Refer to the
Warning on
page110.