![background image](http://html2.mh-extra.com/html/oceanic/atom/atom_operating-manual_3261896145.webp)
145
SPECIFICATIONS (CONTINUED)
DISPLAY RANGE/RESOLUTION
Numeric Displays:
Range:
Resolution:
Dive Number0 to 24
1
Depth
0 to 330 ft (100 m)
1 ft (.1 m )
Maximum Depth
330 ft (100 m)
1 ft (.1 m)
Gas 1 FO2 Set Point
Air, 21 to 50 %
1 %
Gas 2 FO2 Set Point
Air, 21 to 100 %
1 %
Gas 2 FO2 Set Point
Air, 21 to 100 %
1 %
PO2 Value
0.00 to 5.00 ATA
.01 ATA
Dive Time Remaining
0:00 to 9:59 hr:min
1 minute
Air Time Remaining
0:00 to 9:59 hr:min
1 minute
Total Ascent Time
0:00 to 9:59 hr:min
1 minute
Safety Stop Time
5:00 to 0:00 min:sec
1 second
Decompression Stop Time
0:00 to 9:59 hr:min
1 minute
Elapsed Dive Time
0:00 to 9:59 hr:min
1 minute
Surface Interval Time
0:00 to 23:59 hr:min
1 minute
Dive Log Surface Interval
0:00 to 23:59 hr:min
1 minute
Time to Fly
23:50 to 0:00 hr:min*
1 minute
(* starting 10 min after the dive)
Time to Desaturate
23:50 max to 0:00 hr:min*
1 minute
(* starting 10 min. after the dive)
Temperature
0 to 140°F (-9 to 60°C)
1°
Cylinder Pressure
0 to 5000 psi (352 BAR)
5 psi (.5 BAR)
Time of Day
0:00:00 to 23:59:59 hr:min.sec
1 second
Countdown Timer23:59 to 0:00 hr
:min
1 minute
Chronograph
0:00:00.00 to 99:59:59.99
1/100 second
hr:min:sec.1/100 sec
Special Displays:
Occurrence
Out of Range (- - -)
>330 feet (>100 meters)
Violation Countdown Timer
23:50 to 0:00 hr:min (after violation)