101
No Deco Safety Stop Main Display
Information includes (Fig. 89) -
> Tissue Loading Bar Graph
> Transmitter Link icon
> Graphic STOP
> Stop Depth with symbol FT (or M)
> Countdown Stop Time (min:sec) with symbols STOP and TIME
> Dive Time Remaining with symbols NDC (or O2) and TIME
> Current Depth with symbol FT (or M)
> Symbol NITROX (if set for Nitrox)
• Press/release the A button to view Alternate Displays
• Press/hold the A button (2 sec) to view Temperature/Time
• Press/release the L button to activate the Backlight
• Press /release the S button to acknowledge/silence Alarms
Note that the display showing Max Depth and Elapsed Dive Time
will not be available while at the Safety Stop.
DECOMPRESSION DIVE MODE
The ATOM is designed to help you by providing a representation
of how close you are to entering Decompression.
Decompression Dive Mode activates when theoretical No Decom-
pression time and depth limits are exceeded.
Fig. 89 - No Deco Safety
Stop Main