103
The amount of decompression Credit Time that you receive is
dependent on Depth, with slightly less Credit given the deeper
you are below the Stop Depth indicated.
You should stay slightly deeper than the Required Stop Depth
indicated until the next shallower Stop Depth appears. Then, you
can slowly ascend to, but not shallower than that indicated
Ceiling Stop Depth.
Deco Main (Default) Display
information includes (Fig. 92) -
> Tissue Loading Bar Graph (all segments)
> Transmitter Link icon
> Graphics DECO > STOP > xxFT, scrolling (see Warning)
> Stop Depth with symbol FT (or M)
> Stop Time (minutes:seconds) with symbols STOP and TIME
> Total Ascent Time with symbols TOTAL ASCENT and TIME
> Current Depth with symbol FT (or M)
> Symbol NITROX (if set for Nitrox)
• Press/release the A button to view Alternate Displays
• Press/hold the A button (2 sec) to view Temperature/Time
• Press/release the L button to activate the Backlight
• Press/release the S button to acknowledge/silence Alarms
Fig. 92 - Deco Main
WARNING:
If a High PO2
condition occurs
while in Deco
Mode, the
message HIGH >
PO2 will replace
the DECO
message until
PO2 < 1.60.