100
No Deco Secondary Display
information includes (Fig. 88) -
> Day of the Week graphic (MON, TUE, etc.)
> Temperature with icon and graphic F (or C)
> Time of Day (hour:minute:second).
This will be the Default Time selected (Main or Alternate).
• The display will revert to the Main Display after 3 seconds.
No Deco Dive Mode - SAFETY STOP
Upon ascending to the Safety Stop Depth set on any No Decom-
pression dive in which Depth exceeded 30 feet (9 meters), a short
beep will be emitted and a Safety Stop at the Depth set will
appear on the display with a countdown timer that begins at the
Safety Stop Time set and counts down to 0:00 (minutes:seconds).
The Safety Stop will be displayed until the countdown times out,
or you descend below 30 feet (10 meters), or you surface.
There is no Penalty if you surface prior to completing the Safety
Stop.
If the Safety Stop was set to OFF, the screen will not appear
during the ascent.
Fig. 88 - No Deco Secondary