CAUTION: Damage due to improper Battery
replacement is not covered by the product's
limited 2 year warranty.
ATOM (Watch) Battery Removal
• Locate the Battery Compartment on the back of the unit.
• Rotate the Battery Hatch clockwise 10 degrees using the
special Battery Hatch tool provided (Fig. 118A), or by
pushing the lower portion to the left while pushing the upper
portion to the right (Fig. 118B).
• Lift the Hatch with O-ring up and away from the Housing.
• Using care not to damage the Contact (Fig. 119a), slide the
Battery up and out of the Left side of the Battery Compart-
ment.
• Discard the Battery according to local regulations governing
disposal of batteries.
CAUTION: DO NOT allow a metal object to short
circuit the top of the Battery which is positive (+)
to the negative ( - ) contact of the Battery Com-
partment.
Fig. 118A - ATOM
Battery Hatch Removal
Fig. 118B - Alternate
Battery Hatch Removal
Fig. 119 - ATOM Battery
Removal
a
b
c