29
nuaire.co.uk
XBOXER XBC
ECOSMART (CO) MODELS
Backlight
Stand-By-OFF
Home Page
Target
Service Password
0
User Password
0
Stand By
Dark
Stand By Timer
0
Display Settings
Backlight
Stand-By-OFF
Home Page
Target
Service Password
0
User Password
0
Stand By
Dark
Stand By Timer
0
Display Settings
Name
Description
Status
Function
Write
ID
View Config
NS Zone Temp
0°C
NS Zone 1 Temp
0°C
NS Zone 2 Temp
0°C
NS Zone 3 Temp
0°C
Name
Description
Status
Function
Write
ID
View Config
9.0 FC BUS DEVICES
30. 11. 15. Leaflet Number 671710
Figure 23:
Note: If the target page or favourite page is selected as the home page and a
security password is set, the home page will be locked. The only way to exit
the target screen in this case is to press the Nuaire logo to the top right of
the screen for 5 seconds. A security password will then be requested to
access the main menu. The security password timeout is the same as the
standby timer and set via the display settings.
9.5.3 SETTING UP SECURITY
9.5.3.1 TO SET A USER PASSWORD
l
Navigate to the settings page
l
Select the right arrow twice to reach the display settings screen
l
Change the user password a 4 digit number
l
The user password will now be requested each time a locked object
is written
l
The user password is also needed to exit the target page. (When the home
page is set to target)
9.5.3.2 TO SET A SERVICE PASSWORD
l
Navigate to the settings page
l
Select the right arrow twice to reach the display settings screen
l
Change the service password a 4 digit number
l
The service password will now be requested each time the settings page
is accessed
9.5.3.3 TO DISABLE WRITING OF VALUES
l
Navigate to the settings page
l
Select the right arrow six times to reach the View Config screen
l
De-select the write tickbox. All controller points are now read only
l
A service password will need to be set to stop users re-enabling the
write function
9.5.3.4 TO ALLOW BASIC VALUES TO BE WRITTEN BY THE USER
l
Navigate to the settings page
l
Select the right arrow six times to reach the View Config screen
l
Select the function tickbox and lock
l
Select the home icon
l
Navigate to the network page.
l
Select the appropriate controller.
l
Navigate to the required object. See “Exposed BACnet Object List”
for a full list.
l
Select any values that need password protection. A black lock indicates
a locked value
l
When finished, navigate back to the View Config screen in the settings
section. Remove the Function tick and enable writing of values
l
A user password will need to be set to stop writing of locked values.
It is recommended that all values are locked except the following;
Network Page
Description
Object Type
Object ID
32
Enable
MSV
10218
25
Time Schedule
SCH
10496
32
Fan Boost
MSV
10240
28
Heat Boost
MSV
10205
15
Software Setpoint
AV
10309
Summary of Contents for ecosmart CONNECT XBOXER XBC
Page 51: ...51 nuaire co uk XBOXER XBC ECOSMART CO MODELS 30 11 15 Leaflet Number 671710...
Page 52: ...029 2085 8200 52 XBOXER XBC ECOSMART CO MODELS Figure 35 13 0 DIAGRAMS 13 4 PHYSICAL LAYOUT...
Page 53: ...53 nuaire co uk XBOXER XBC ECOSMART CO MODELS 30 11 15 Leaflet Number 671710...
Page 55: ...55 nuaire co uk XBOXER XBC ECOSMART CO MODELS 30 11 15 Leaflet Number 671710...
Page 57: ...57 nuaire co uk XBOXER XBC ECOSMART CO MODELS 30 11 15 Leaflet Number 671710...
Page 59: ...59 nuaire co uk XBOXER XBC ECOSMART CO MODELS 30 11 15 Leaflet Number 671710...
Page 61: ...61 nuaire co uk XBOXER XBC ECOSMART CO MODELS 30 11 15 Leaflet Number 671710...