SPLITMUX Quad Screen 4K 18GB Multiviewer
76
In Figure 74, it is indicated that one level of SPLITMUX is connected through channel 2 (Input 2). This is IP 192.168.3.183.
Notice that in Cascade Settings the slave (192.168.3.183) is configured for connection to Input 2, and the upstream slave
(192.168.3.173) is connected to the output. Other input ports are configured for direct connection to input sources.
Any edits made using the web interface configuration menu at this level will directly and only impact the SPLITMUX at IP
192.168.3.125.
To switch to the last slave in that configuration (IP 192.168.3.183), double-click on channel 2.
To switch back to the configuration of the master or upper level slave, click on the appropriate tab.
Figure 75- View of custom configuration of Slave at IP 192.168.3.183
In Figure 75, we see that there are no slaves connected to this SPLITMUX. In Cascade Settings, only the output master IP
address is configured.
At each configuration level, the Current Mode setting will dictate what is viewed upstream at the output, regardless of how the
custom layout is configured. The custom layout will only impact what is viewed if the Current Mode is set to “Custom” (page 17).
The audio is impacted in the same fashion. If the audio from an input on the lowest-level slave is desired, the configured input
channel for each higher level slave must be set to pass that audio signal, all the way through to the master.
Figure 76- Current output mode selection
tabs showing hierarchy of configuration