GENERAL MAINTENANCE
K JAW BLADE MAINTENANCE AND ADJUSTMENT
There should be no gap (d95) between primary blades, the piercing tip, and the straight
edge. If the blades are being turned and a gap (d3) is found between either of the
blades and the straight edge, measure the gap using feeler gauges and add shims as
required. If the gap is found at the piercing tip, the primary blade or blades may require
surface grinding at a machine shop. If the gap between the primary blades and the
piercing tip is excessive, install new primary blades.
It is imperative that the primary blade faces are parallel/even in order to achieve correct
blade clearance between the primary and secondary blades. Once the primary blades
are in place, use thread adhesive (t41) on the socket head cap screws (OO). Then
torque to NPK specifications (see the
“FASTENER TORQUE CHART”
).