104
-
TROUBLESHOOTING
SLOW CYCLE SPEED
The specified cycle times of the M35 Material Processor are controlled by the flow
provided by the hydraulic circuit of the carrier. The published cycle times of the M35
Material Processor are a direct result of the maximum published oil flow; see the
“MODEL SPECIFICATIONS”
section of this instruction manual.
NOTE:
If the jaws will not open or close, be sure the open and close shut-off valves are
in the
“ON”
position.
Tools and equipment required:
(For carriers with an NPK hydraulic installation kit installed.)
Pressure gauge (g8f): 5000 psi
(350 bar)
.
Test port adapter (g20): to fit #4 SAE female port in NPK shut-off valve (k4).
Test hose (t81): 5000 psi
(350 bar)
rated.
Loading type hydraulic flow meter (t36): 100 gpm
(380 l/m)
hydraulic flow capacity.
TEST PROCEDURE
Install a pressure gauge in the test port of the jaw close circuit
(left shut-off valve as
seen from the operator’s position)
. Fully stroke the M35 Material Processor cylinders.
Measure the attachment operating pressure.
SLOW CYLINDER SPEED
PROBLEM
CAUSE
CHECK
REMEDY
Slow cylinder
speed. Operating
pressure is at 3,700
psi (
255 bar
), but
the intensifier does
not click.
Carrier flow setting
is set too low.
Check flow output of
M35 Material
Processor hydraulic
circuit at 1000 psi (
69
bar
).
Adjust carrier flow
output to meet NPK
specifications.
Repair or replace the
carrier's pump.
M35 Material
Processor
cylinders.
Check piston rings in
M35 Material
Processor cylinders.
Replace if damaged
or worn.