-
94
-
TROUBLESHOOTING
TROUBLESHOOTING GUIDE FOR LOW POWER
RELIEF VALVE CHECKS
LOW POWER CHECKS
PROBLEM
CAUSE
CHECK
REMEDY
Operating Pressure
is less than 3,700
psi (
255 bar
).
Carrier hydraulic
circuit relief valve.
Measure the carrier
circuit relief valve with
the pressure to close
shut-off valve in the
"OFF"
position
Adjust or replace the
carrier circuit relief
valve. The setting for
the relief valve must
be 200 psi (
14 bar
),
minimum, above the
M35 Processor
operating pressure.
M35 Processor
relief valves
Measure the relief
valves with the shut-
off valves on the
carrier in the
"ON"
position. Check
pressure with the
jaws fully open and
fully closed.
Setting should be
3,700 psi (
255 bar
)
Check relief
cartridges for
tightness.
Tighten the relief
valve cartridges.
Check relief
cartridges for mis-
adjustment.
Reset to 3,700 psi
(
255 bar
). If unable
to adjust, replace the
cartridge.
Check the o-rings and
backup rings of the
relief valve cartridges.
Replace the o-rings
and backup rings of
both relief valve
cartridges.
Pilot check valve
assemblies.
Inspect the booster
inlet pilot check
valves for damage.
Replace the inlet
pilot check valve
assemblies if
necessary.
Swivel manifold
assembly
Check the seals
between the open
and close passages
in the swivel manifold
assembly.
Replace the seals in
the swivel manifold
assembly.
Check the land areas
for the seals in the
swivel manifold
assembly.
Repair the land area
or replace the
spindle.
Summary of Contents for M35G
Page 13: ... 13 SERIAL NUMBER LOCATION M35 ...
Page 115: ... 115 WARRANTY STATEMENTS ...
Page 116: ... 116 WARRANTY STATEMENTS ...